[quote name='Mr. Foxen' post='1287143' date='Jun 29 2011, 11:21 PM']Clening is done. The stuff involving a meter I haven't done, don't really know what I'm up to with it. how would I check the transformer for shorts?
All the electrolytics have been replaced.
Sop fire it up without valves in and stick the meter in the valve bases, what voltages am I looking for in there, on what pin numbers (actually caught myself there, then realised that is valid use of the phrase 'pin number').[/quote]
[url="http://tdsl.duncanamps.com/show.php?des=EL34"]http://tdsl.duncanamps.com/show.php?des=EL34[/url]
should have the HT on pin 3 - about 530 - 540V without valves in and a little less on pin 4
3.3v AC on pins 2 and 7
bias will be negative voltage on top end of that upside down cap, follow it along to bias pots etc.
to check transformers just measure resistance across the windings etc.